Humidity Tips
Weather Monitor II Page 41
HUMIDITY TIPS
Inside humidity seems too high or low
Make sure the console is not near a humidifier or de-humidifier.
Check calibration number and adjust if necessary.
WIND TIPS
Wind speed reading seems lower than expected
Check installation by spinning wing cups. If you get a reading, the wind
cups are installed correctly. Wind speed reads 0 either all the time or inter-
mittently
Make sure anemometer cable is plugged into jack marked WIND on junc-
tion box.
Check for broken wire along length of anemometer cable. Carefully check
areas where the cable has been secured.
If you still do not get a reading, the problem is probably with the anemome-
ter. Call factory for return authorization.
Wind speed reading seems too high or too low
Check calibration number and adjust if necessary.
Wind direction reading is dashed out
Make sure anemometer cable is plugged into jack marked WIND on junc-
tion box.
Check for broken wire along length of anemometer cable. Check the areas
where the cable has been secured carefully.
If these steps do not reveal the problem, the problem is probably with the
anemometer. Call the factory for return authorization.
WIND CHILL TIPS
Wind chill reading seems too high or too low
Check calibration number for temperature and wind speed. Adjust if neces-
sary.